1506 Brushy View Cv
Austin, TX 78754 Issued Jun 18, 2026
Scope of work
Installation of: OFF-GRID PV + Battery System System Size: SOLAR PV: 7.2 kW-DC/11.4 kW-AC BATTERY: 15kWh Modules: 16 CW ENERGY: CWT450-108TNB10 - 450W Inverter(s): 1 Franklin WH inverter battery: APOWER S-10 APRS-10K15V1-US Other: 1 Franklin WH mid: agate x 1 Franklin WH inverter battery: APOWER S-10 APRS-10K15V1-US 1 main service panel: 125A 1 MLO PANEL: 125A 1 EV charging receptacle: 120V NEMA 14-50 Notes: OFF-GRID System: NOT interconnecting with Austin Energy grid PV array inverter battery aGate main service panel & EV charger to be located on existing carport. TRENCH: APPROXIMATELY 65 ft - at least 18 depth above conduit per NEC 300.5 mlo panel to be located inside workshop
Permit timeline
- AppliedJun 15, 20263 days in review
- IssuedJun 18, 20263mo ago
- ExpiresDec 15, 2026in 63 days
Details
- Project type
- Electrical Permit
- Work class
- Repair
- Sector
- Residential
- Permit type
- Electrical Permit
- Council district
- 1
- ZIP code
- 78754
- Status
- Active
- Permit no.
- 2026-075947 EP