10724 E Sebring Ave
Mesa, AZ 85212 Issued May 7, 2026 Renovation / remodel
Declared value
$2.5K$2,500
Size
Not reported
Floors
Not reported
Units
Not reported
Scope of work
Otc - approved by chris clark - divide equally front & back attach 2X scab of the same size and grade as the broken member to each face of the truss (center on break or splice) WITH 10d (0.131"X3" NAILS (2 ROWS FOR 2X4, 3 ROWS FOR 2X6). SPACED 4" O.C. AS SHOWN. Stagger nail spacing from front face and back face for a net 0-2-0 O.C. Spacing in the main member. Use a min. 0-3-0 member end distance. The length of the break (C) shall not exceed 12". (C=plate length for splice repairs) the minimum overall scab length required (L) is calculated as follows: L = (2) X + C
Permit timeline
- AppliedMay 6, 20261 day in review
- IssuedMay 7, 20265mo ago
- CompletedJun 12, 20264mo ago
Details
- Project type
- Renovation / remodel
- Work class
- Renovations/Remodels
- Sector
- Residential
- Permit type
- Residential Permit
- Council district
- 6
- ZIP code
- 85212
- Status
- Certificate of completion issued
- Permit no.
- PMT26-08641