Roofing Completed

1212 Valence St

New Orleans, LA 70115 Issued Jul 6, 2026 Roof replacement

Declared value Not reportedThe city gave no value
Size Not reported
Floors Not reported
Units Not reported

Scope of work

1. Removal and Disposal: Remove, haul, tear-off, and dispose of one layer of the existing roof. 2. Roof Deck Nailing: Nail the existing roof deck with 8d ring-shank nails spaced at 4 inches on center per F-RR-3 standards. 3. Deck Sealing: Install deck tape on decking seams across the entire roof to enhance sealing. 4. Waterproofing: Install Weatherlock Owens Corning Ice & Water Shield per local building codes. Use WeatherLock® Mat Self-Sealing Ice & Water Barrier in valleys and around openings. 5. Underlayment: Install double layer of RhinoRoof synthetic underlayment for additional moisture and wind-driven rain protection. This creates a bond break between the shingles and the Ice-and-Water shield. 6. Drip Edge: Replace the existing drip edge with a new fortified drip edge that extends 1/2 inch below the sheathing and a minimum of 2 inches back onto the roof. Secure the drip edge to the roof deck with mechanical fasteners at a maximum of 4inches apart. 7. Starter Shingles: Install Owens Corning double-sided starter shingle rolls along the entire perimeter of the roof. 8. Shingles: Use Owens Corning™ DURATION® 9. Hip & Ridge Shingles: Install Owens Corning™ PROEDGE® Hip & Ridge Shingles. 10. Ridge Vent: Install Owens Corning ridge vent/ eave vents for proper ventilation. 11. Bullet Boots12. Flashing: Once all applicable photos have been uploaded, please email requesting permit closure

Permit timeline

  1. AppliedJun 30, 20266 days in review
  2. IssuedJul 6, 20263mo ago
  3. CompletedAug 26, 20267w ago

Details

Project type
Roof replacement
Work class
Single Family
Sector
Residential
Permit type
Residential Re-Roofing
City
New Orleans, LA
ZIP code
70115
Status
Finaled
Permit no.
26-19246-ROOF