New build 2 permits in this project Active

2204 Alexander Ave Bldg 1

Austin, TX 78722 Issued Oct 12, 2026 Duplex

Declared value Not reportedThe city gave no value
Size 2,793sqftThis permit only
Floors 2
Units 2

Scope of work

BUILD 1 New construction of two dwelling units joined with a covered screened porch attached carport raised terrace and uncovered wood deck. New driveway approach leading to a ribbon driveway 1/1.5 Revision: Permit Revision Narrative: This resubmittal documents three major revisions to the approved permit drawings for this residential development. 1. Conditioned Square Footage Unit 1: The total conditioned square footage for Unit 1 increased to include an enclosed dining room. The screened porch from the previous design is no longer part of the project scope. There are no other permit relevant revisions to Unit 1. Unit 2: The floor plan layout of Unit 2 has been revised. Floor plan on A1.2 show updated visitable route and bathroom smoke/carbon monoxide detector locations attic access and call out square footage and ceiling heights by space. Escape and rescue openings are called out in the window and door schedules on sheet A1.3. Shared Accessory Room: Introduced a new shared accessory room between Unit 1 & Unit 2. Updated FAR calculations are provided on A0.1. 2. Building Footprint & Envelope The proposed revision required minor adjustments to the building footprint & foundation. As part of the revised design the footprint of the wood deck also adjusted. Updated impervious cover and total building coverage calculations are provided on A0.1. Revisions to openings and new openings are shown in the updated window and door schedules on sheet A1.3. 3. Fire Separation Between Dwelling Units The revised design locates a shared accessory room per 2024 IRC R302.3.6 between Unit 1 and Unit 2. The function of the shared accessory room is to provide a storage space accessible from both units. The walls between the shared accessory room and dwelling units are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation and separation requirements are vertically continuous from foundation to roof deck. Structures supporting the ceiling of the shared accessory room are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation. There is no habitable space above or below the shared accessory room. All openings in walls separating dwelling units from the shared accessory room are compliant with R302.3.6.1 Opening Protection. All duct penetrations shall comply with R302.3.6.2 and shall not have openings into the shared accessory room. All other penetrations shall comply with R302.3.6.3. See A0.2 Fire Separation & Details for updated code compliance diagrams.

Permit timeline

  1. AppliedJul 11, 202515 months to issue
  2. IssuedOct 12, 2026Yesterday
  3. ExpiresApr 11, 2027in 180 days

Details

Project type
Duplex
Work class
New
Sector
Residential
Permit type
Building Permit
Council district
1
ZIP code
78722
Status
Active
Permit no.
2025-137955 BP

All permits in this project 2

New build 2204 Alexander Ave Bldg 1BUILD 1 New construction of two dwelling units joined with a covered screened porch attached carport raised terrace and uncovered wood deck. New driveway approach leading to a ribbon driveway 1/1.5 Revision: Permit Revision Narrative: This resubmittal documents three major revisions to the approved permit drawings for this residential development. 1. Conditioned Square Footage Unit 1: The total conditioned square footage for Unit 1 increased to include an enclosed dining room. The screened porch from the previous design is no longer part of the project scope. There are no other permit relevant revisions to Unit 1. Unit 2: The floor plan layout of Unit 2 has been revised. Floor plan on A1.2 show updated visitable route and bathroom smoke/carbon monoxide detector locations attic access and call out square footage and ceiling heights by space. Escape and rescue openings are called out in the window and door schedules on sheet A1.3. Shared Accessory Room: Introduced a new shared accessory room between Unit 1 & Unit 2. Updated FAR calculations are provided on A0.1. 2. Building Footprint & Envelope The proposed revision required minor adjustments to the building footprint & foundation. As part of the revised design the footprint of the wood deck also adjusted. Updated impervious cover and total building coverage calculations are provided on A0.1. Revisions to openings and new openings are shown in the updated window and door schedules on sheet A1.3. 3. Fire Separation Between Dwelling Units The revised design locates a shared accessory room per 2024 IRC R302.3.6 between Unit 1 and Unit 2. The function of the shared accessory room is to provide a storage space accessible from both units. The walls between the shared accessory room and dwelling units are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation and separation requirements are vertically continuous from foundation to roof deck. Structures supporting the ceiling of the shared accessory room are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation. There is no habitable space above or below the shared accessory room. All openings in walls separating dwelling units from the shared accessory room are compliant with R302.3.6.1 Opening Protection. All duct penetrations shall comply with R302.3.6.2 and shall not have openings into the shared accessory room. All other penetrations shall comply with R302.3.6.3. See A0.2 Fire Separation & Details for updated code compliance diagrams. Yesterday · 2,793 sqft THIS PERMIT New build 2204 Alexander Ave Bldg 2BUILDING 2 1 STORY SFR 2/1 rear of main house Revision: Permit Revision Narrative: This resubmittal documents three major revisions to the approved permit drawings for this residential development. 1. Conditioned Square Footage Unit 1: The total conditioned square footage for Unit 1 increased to include an enclosed dining room. The screened porch from the previous design is no longer part of the project scope. There are no other permit relevant revisions to Unit 1. Unit 2: The floor plan layout of Unit 2 has been revised. Floor plan on A1.2 show updated visitable route and bathroom smoke/carbon monoxide detector locations attic access and call out square footage and ceiling heights by space. Escape and rescue openings are called out in the window and door schedules on sheet A1.3. Shared Accessory Room: Introduced a new shared accessory room between Unit 1 & Unit 2. Updated FAR calculations are provided on A0.1. 2. Building Footprint & Envelope The proposed revision required minor adjustments to the building footprint & foundation. As part of the revised design the footprint of the wood deck also adjusted. Updated impervious cover and total building coverage calculations are provided on A0.1. Revisions to openings and new openings are shown in the updated window and door schedules on sheet A1.3. 3. Fire Separation Between Dwelling Units The revised design locates a shared accessory room per 2024 IRC R302.3.6 between Unit 1 and Unit 2. The function of the shared accessory room is to provide a storage space accessible from both units. The walls between the shared accessory room and dwelling units are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation and separation requirements are vertically continuous from foundation to roof deck. Structures supporting the ceiling of the shared accessory room are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation. There is no habitable space above or below the shared accessory room. All openings in walls separating dwelling units from the shared accessory room are compliant with R302.3.6.1 Opening Protection. All duct penetrations shall comply with R302.3.6.2 and shall not have openings into the shared accessory room. All other penetrations shall comply with R302.3.6.3. See A0.2 Fire Separation & Details for updated code compliance diagrams. Yesterday · 644 sqft