Remodel 5 permits in this project Issued

10256 E Elliot Rd

Mesa, AZ 85212 Issued Aug 13, 2026 Tenant improvement

Declared value $19.8M$19,839,939, whole project
Size 27,679sqftThis permit only
Floors Not reported
Units Not reported

Scope of work

Tenant improvement of 27,679 SF Vault 2.2 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs & railings. Deferred fire sprinklers, fire alarms, and generators. Approved with notes. Results in Partial CoO.

Permit timeline

  1. AppliedDec 31, 2025225 days in review
  2. IssuedAug 13, 20262mo ago
  3. StatusIssuedWork in progress

Details

Project type
Tenant improvement
Work class
Tenant Improvement (Interior Only)
Sector
Commercial
Permit type
Commercial Permit
Council district
6
ZIP code
85212
Status
Issued
Permit no.
PMT25-23755

All permits in this project 5

Remodel 10256 E Elliot RdTenant improvement of 27,679 SF Vault 2.2 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs & railings. Deferred fire sprinklers, fire alarms, and generators. Approved with notes. Results in Partial CoO. 2mo ago · 27,679 sqft THIS PERMIT Remodel 10256 E Elliot RdTenant improvement of 27,683 SF Vault 2.3 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs & railings. Deferred fire sprinklers, fire alarms, and generators. Approved with notes. Results in Partial CoO. 3mo ago · 27,683 sqft Remodel 10256 E Elliot RdTenant improvement of 27,693 SF Vault 1.2 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs & railings. Deferred fire sprinklers, fire alarms, and generators. Approved with notes. Results in Partial CoO. 3mo ago · 27,693 sqft Remodel 10256 E Elliot RdTenant improvement of 27,674 SF Vault 1.2 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs & railings. Deferred fire sprinklers, fire alarms, and generators. Approved with notes. Results in Partial CoO. 3mo ago · 27,674 sqft Remodel 10256 E Elliot RdTenant improvement of 27,681 SF Vault 1.3 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs & railings. Deferred fire sprinklers, fire alarms, and generators. Approved with notes. Results in Partial CoO. 3mo ago · 27,681 sqft